Edit Terminals

From WireCAD Online Help
Revision as of 19:55, 7 January 2015 by Wirecadadmin (Talk | contribs)

Jump to: navigation, search

Overview

You can edit terminals (Jacks, Terminals, Pointers) to show hidden attributes. 

There are several rules that you must adhere to in order to be successful. A breif outline of the rules follows with more detail in the article below:

  1. Terminals that the program uses will reside in the %BLOCKS% support path.
  2. You may only edit terminals with the WC3_xxx_yy.DWG naming convetion. These are terminals that have the editable attribute set.
  3. You must not delete any attribute that you wish not shown. Rather you should mark it as invisible by setting its InvisibleMode=true.
  4. You should rename your edited versions of the file following the required naming convention.



Available Attributes in All WC3_xx_xx.dwg Terminals

All WC3 terminals have the following attributes (though many of them may be marked as inviisible):

  • SysName
  • EquipmentName - Not always populated
  • ManufacturerName
  • Location
  • Alias
  • SheetRef
  • CreatedWith
  • EquipmentID
  • WC_TYPE
  • EquipmentDescription

All WC3 terminals will have at least one CP_IN or one CP_OUT attribute or both.

In addition to the CP_IN and CP_OUT attribute the terminal may also contain display attributes for the connection point data such as:

  • INPUT_NAME
  • INPUT_CONN
  • OUtPUT_NAME
  • OUTPUT_CONN



File Naming Convention

Terminal file name suffixes determine where the terminal is displayed in the application. 

Terminals that are suffixed: _SD.dwg or _S.dwg will appear in the list of source terminals.

Terminals that are suffixed _SD.dwg or _D.dwg will appear in the list of destination terminals.

If a terminal has only a CP_IN attribute it should be suffixed _D.dwg. This will tell the program to put it in the terminal desitinations list.

If a terminal has only a CP_OUT attribute it should be suffixed _S.dwg. This will tell the program to put it in the terminal sources list.

A terminal that has both a CP_IN and a CP_OUT attribute should be suffxed _SD.dwg  to allow it to be visible in both lists.


FAQ

Q: Can I edit Pointer_S.dwg to show the alias.

A: No. Pointer_S.dwg and Pointer_D.dwg are legacy terminals that do not possess all the attributes.