Knowledge Base
Knowledge BaseSubject: | "Cable#" not populating based on cable sysname |
---|---|
Status |
Resolved |
Product | WireCAD v8 |
Product Level | PRO |
Database Type | SQL Server |
Build Number (last 4 digits of version) | 1382 |
Message
I've got my drawing all done and my gear has sysnames. I'm trying to assign cable numbers but it's not taking. We tried on two computers, no luck.
I noticed that when I select a block and use the arrow keys to move it up or down, the cable doesn't stay connected and move with it. Could that be related?
Also, in a side note: I can't get that pointer reference letter script to add any letters.
I noticed that when I select a block and use the arrow keys to move it up or down, the cable doesn't stay connected and move with it. Could that be related?
Also, in a side note: I can't get that pointer reference letter script to add any letters.
16-November-2016 (10:31 AM)
Found corrupt drawing. Recommended pasting entities into new drawing. Worked.
Script needed tweaking to including the source pointer name.
Script needed tweaking to including the source pointer name.
17-November-2016 (10:04 AM)