<< Click to Display Table of Contents >> RatsNest |
|
Menu: Advanced Tools>AutoScheme Tools>RatsNest
Default command line shortcut: rn
Related Settings:
None
The RatsNest tool checks the project cables database against the drawing. If connections defined in the cables database can be reproduced in the drawing because the SysNames and Ports exist, a cable is placed.
This tool requires that the Project Cables table be populated.
•This tool has three sections. The Rats Nest section does the work of placing the cables in the drawing as defined in the Cables database.
•[Ratsnest] - Run the utility to place the cables.
•Show Cable Numbers - With or without cable numbers.
•[Clear All Cables] - Removes ALL cables from the drawing. Not just ratsnested cables. This will remove ALL.
•[Cleanup] - Applies the auto-router to all cables in the drawing.
•Avoid Other Cables - Auto-router avoids other cables on cleanup.
•[Fillet] - Applies fillets to ALL cables in the drawing.
•Distance - Fillet distance in 100/DU.